251 research outputs found

    Testes de acurácia para o serviço e técnica GNSS/NTRIP

    Get PDF
    Experiments conducted at the School of Engineering of the University of São Paulo, Brazil, using GNSS/NTRIP technology are described and analyzed in terms of accuracy. The method consists in using the data of a reference station, the IBGE RBMC-IP stations, collected in a remote station, by means of the Internet and a mobile phone, to obtain more accurate real time coordinates than those of the navigation method. The experiments consist in surveying the known coordinate points and of the error analysis (accuracy). Firstly with short distances (in the USP Base for Equipment Calibration), and then over increasing distances up to about 30 km, in terms of the limits foreseen for the RTK method, and for other greater distances by using the DGPS method, up to 2,700 km. The following were tested and analyzed: the use of different reference stations, the variation in accuracy over distance, the use of a L1 receiver and a L1/L2 one, as well as the use of the RTK and DGPS techniques, in terms of accuracy reached, that is, the difference between these coordinates and others considered as standard, besides checking if the equipment reaches or not the accuracy stated in the manual.O presente trabalho descreve e analisa as experiências realizadas na Escola Politécnica utilizando a tecnologia GNSS/NTRIP, em termos de acurácia. O método consiste em utilizar os dados de uma estação de referência, no caso estações da RBMC-IP do IBGE, coletados na estação remota, através de internet e telefonia celular para obter em tempo real coordenadas com maior precisão que as do método de navegação. Os experimentos consistiram no levantamento de pontos de coordenadas conhecidas e análise dos erros obtidos. Primeiro em distâncias curtas na base USP de calibração de equipamentos e, a seguir, em distâncias crescentes até aproximadamente 30 km, em função dos limites previstos para o método RTK; e também para distâncias maiores utilizando o método DGPS, até 2.700 km. Foram testados e analisados: o uso de diferentes estações de referência; a variação da acurácia com a distância; o uso de um receptor L1 e outro L1/L2, bem como o uso das técnicas RTK e DGPS em termos de acurácia, isto é, a diferença entre essas coordenadas e aquelas consideradas como padrão, verificando se os equipamentos atingem os valores previstos nas especificações técnicas

    Estudo de caso de eficiência energética e controle de qualidade do ar interior em ambiente condicionado

    Get PDF
    Trabalho de Conclusão de Curso (graduação)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2018.O objetivo deste trabalho é realizar um estudo de caso sobre eficiência energética e controle de qualidade do ar interior (QAI) de sistema de ar condicionado com tecnologias de vazão de ar exterior variável (DCV), recuperação de energia (ERV) e free cooling no plenário Ulysses Guimarães, Brasília - DF. Uma simulação computacional com auxílio dos softwares OpenStudio e Energyplus acerca do sistema de climatização em estudo foi realizada para analisar o potencial de economia na utilização de recursos como ERV, DCV e free cooling. Para tal, foram consideradas condições climáticas locais, características arquitetônicas do plenário, bem como as eficiências dos equipamentos utilizados. Paralelamente, foi realizada uma avaliação da qualidade do ar interior e possíveis soluções de monitoramento. Os resultados mostraram que a combinação das tecnologias avaliadas foi capaz de proporcionar economias de até 20% nos custos operacionais do sistema de ar condicionado em ambientes que apresentam perfil de ocupação variável.The objective of this work is to perform a case study on energy efficiency and indoor air quality control (IAQ) of air conditioning system with variable outdoor airflow (DCV), energy recovery (ERV) and free cooling technologies in plenary Ulysses Guimarães, Brasilia DF. A computer simulation with the help of the OpenStudio and Energyplus software on the air conditioning system under study was performed to analyze the potential savings in the use of resources such as ERV, DCV and free cooling. For this, local climatic conditions, architecture characteristics of the plenary, as well as the efficiencies of the equipment used were considered. At the same time, an indoor air quality assessment and possible monitoring solutions were carried out. The results showed that the combination of the technologies evaluated was able to provide savings up to 20% in the operating costs of the air conditioning system in environments with variable occupancy profiles

    GNSS/NTRIP SERVICE AND TECHNIQUE: ACCURACY TESTS

    Get PDF
    Experiments conducted at the School of Engineering of the University of São Paulo, Brazil, using GNSS/NTRIP technology are described and analyzed in terms of accuracy. The method consists in using the data of a reference station, the IBGE RBMC-IP stations, collected in a remote station, by means of the Internet and a mobile phone, to obtain more accurate real time coordinates than those of the navigation method. The experiments consist in surveying the known coordinate points and of the error analysis (accuracy). Firstly with short distances (in the USP Base for Equipment Calibration), and then over increasing distances up to about 30 km, in terms of the limits foreseen for the RTK method, and for other greater distances by using the DGPS method, up to 2,700 km. The following were tested and analyzed: the use of different reference stations, the variation in accuracy over distance, the use of a L1 receiver and a L1/L2 one, as well as the use of the RTK and DGPS techniques, in terms of accuracy reached, that is, the difference between these coordinates and others considered as standard, besides checking if the equipment reaches or not the accuracy stated in the manual

    Causa mortis em usuários de crack

    Get PDF
    OBJECTIVE: The study accompanied 131 crack-cocaine users over a 5-year period, and examined mortality patterns, as well as the causes of death among them. METHOD: All patients admitted to a detoxification unit in São Paulo between 1992 and 1994 were interviewed during two follow-up periods: 1995-1996 and 1998-1999. RESULTS: After 5 years, 124 patients were localized (95%). By the study endpoint (1999), 23 patients (17.6%) had died. Homicide was the most prevalent cause of death (n = 13). Almost one third of the deaths were due to the HIV infection, especially among those with a history of intravenous drug use. Less than 10% died from overdose. CONCLUSIONS: The study suggests that the mortality risk among crack cocaine users is greater than that seen in the general population, being homicide and AIDS the most common causes of death among such individuals.OBJETIVO: O estudo acompanhou, por cinco anos, um grupo de 131 usuários de crack e observou os padrões de mortalidade, bem como as causas mortis entre esses. MÉTODO: Todos os pacientes que se internaram em um serviço de desintoxicação, localizado no município de São Paulo, entre 1992-1994 foram entrevistados em duas ocasiões: 1995-1996 e 1998-1999. RESULTADOS: Após cinco anos, 124 pacientes foram localizados (95%). Vinte e três pacientes (17,6%) haviam morrido ao final do quinto ano de seguimento, sendo os homicídios a causa mortis mais prevalente (n = 13). Quase um terço dos pacientes morreu devido à infecção pelo vírus da imunodeficiência adquirida (HIV), especialmente aqueles com antecedentes pessoais de uso de drogas endovenosas. Menos de 10% dos pacientes morreu de overdose. CONCLUSÕES: O estudo sugere que os usuários de crack têm maior risco de morte do que a população geral, sendo os homicídios e a AIDS as causas mais observadas.Universidade Federal de São Paulo (UNIFESP) Department of Psychiatry Unidade de Pesquisa em Álcool e DrogasCamden & Islington Mental Health & Social Care Trust North Camden Drug ServiceGrupo Interdepartamental de Epidemiologia ClínicaUniversidade Federal de São Paulo (UNIFESP)UNIFESP, Department of Psychiatry Unidade de Pesquisa em Álcool e DrogasUNIFESPSciEL

    ATOM: Atomic Durability in Non-volatile Memory through Hardware Logging

    Get PDF
    corecore